UL 1354 # 28 (AL + B) Coaxial Cable |
 |
|
|
Conductor: |
|
|
Annealed Copper Wire (Bare or Tinned Strand) |
Insulation: |
|
|
| CPE ( Cellular Polyethylene) |
shield: |
| Aluminum-Mylar Tape and Annealed Copper Wire (Tinned Copper ) |
Sheath: |
| PVC ( Polyvinyl Chloride) |
Structure: |
Conductor |
CPE Insulation |
Braid Shield |
Sheath |
AWG |
Construction |
Diameter |
Min. Thickness |
Nominal
Thickness |
Diameter |
Construction |
Diameter |
Min.
Thickness |
Nominal
Thickness |
Diameter |
28 |
7 / 0.13TA |
approx.
0.41 mm |
0.45 mm |
0.53 mm |
1.45 ± 0.10 mm |
16/5/0.10 |
approx.
2.00 mm |
0.36mm |
0.55mm |
3.10 ± 0.10 mm |
|
| |
| |
Characteristics: |
| |
Items |
Specification |
Rating |
UL:80℃ 30V |
Dielectric Strength |
AC 500V / min.
(Between Conductor and Shield) |
Spark Test AC 2000V / 0.15sec. |
Insulation Resistance |
Min.1000MW - Km (20℃) at DC 500V |
|
| |
|
|
|