| UL 1478 Coaxial Cable |
 |
|
|
Product Description : |
|
|
Cables now have to accommodate higher signal rate over longer distances with lower signal loss.
Moreover, new shielding requirements to meet FCC signal loss, FCC RFI/EMI emission controls,
tougher fire regulations requiring low toxicity materials in plenum installations and demands |
Type Designation : |
|
|
| RG-6/U |
Construction : |
Type |
UL
Style |
Conductor |
Insulation |
Braid Shield |
Jacket |
Nom. Imped. |
Nom. Cap. |
Attenuation
100MHz |
Standard Put-up |
No./mm |
MTRL |
mm |
MTRL |
No./mm |
No./mm |
MTRL |
mm |
MTRL |
Ohm |
pf/m |
dB/km |
ft/coil |
M/coil |
RG-5/U |
- |
1/1.29 |
BC |
4.7 |
LDPE |
16/9/0.16 |
24/8/0.16 |
BC |
8.4± 0.20 |
PVC |
52.5 |
93.5 |
85 |
328 |
100 |
RG-6/U |
1354 |
1/1.024 |
CCS |
4.57 |
LDPEF |
16/9/0.16 |
16/8/0.16 |
TC |
7.4± 0.20 |
PVC |
75 |
56.8 |
69 |
328 |
100 |
RG-7/U |
- |
1/0.914 |
BC |
6.35 |
LDPE |
24/7/0.18 |
|
BC |
9.4± 0.20 |
PVC |
94.5 |
41.0 |
66 |
328 |
100 |
RG-8/U |
1354 |
7/0.724 |
BC |
7.24 |
LDPE |
24/8/0.18 |
|
BC |
10.3± 0.20 |
PVC |
52 |
96.8 |
69 |
328 |
100 |
RG-8A/U |
1354 |
7/0.724 |
BC |
7.24 |
LDPE |
24/8/0.18 |
|
BC |
10.3± 0.20 |
NC- PVC |
52 |
96.8 |
69 |
328 |
100 |
RG-11/U |
1354 |
7/0.404 |
TC |
7.24 |
LDPE |
24/8/0.18 |
|
BC |
10.3± 0.20 |
PVC |
75 |
67.3 |
76 |
328 |
100 |
RG-11A/U |
1354 |
7/0.404 |
TC |
7.24 |
LDPE |
24/8/0.18 |
|
BC |
10.3± 0.20 |
NC- PVC |
75 |
67.3 |
76 |
328 |
100 |
RG-13/U |
1354 |
7/0.404 |
TC |
7.11 |
LDPE |
24/9/0.16 |
24/8/0.16 |
BC |
10.7± 0.20 |
PVC |
74 |
67.3 |
76 |
328 |
100 |
RG-13A/U |
1354 |
7/0.404 |
TC |
7.11 |
LDPE |
24/9/0.16 |
24/8/0.16 |
BC |
10.7± 0.20 |
NC- PVC |
74 |
67.3 |
76 |
328 |
100 |
RG-14/U |
- |
1/2.59 |
BC |
9.40 |
LDPE |
24/10/.018 |
24/8/0.18 |
BC |
13.8± 0.20 |
PVC |
52 |
96.8 |
46 |
328 |
100 |
RG-14A/U |
- |
1/2.59 |
BC |
9.40 |
LDPE |
24/10/.018 |
24/8/0.18 |
TC |
13.8± 0.20 |
NC- PVC |
52 |
96.8 |
46 |
328 |
100 |
RG-15/U |
- |
1/1.45 |
CCS |
9.40 |
LDPE |
24/10/.018 |
24/8/0.18 |
BC |
13.8± 0.20 |
PVC |
76 |
65.6 |
49 |
328 |
100 |
RG-17/U |
- |
1/4.78 |
BC |
17.3 |
LDPE |
24/14/0.255 |
|
BC |
22.1± 0.35 |
PVC |
52 |
96.8 |
28 |
328 |
100 |
RG-17A/U |
- |
1/4.78 |
BC |
17.3 |
LDPE |
24/14/0.255 |
|
BC |
22.1± 0.35 |
NC- PVC |
52 |
96.8 |
28 |
328 |
100 |
RG-19/U |
- |
1/6.35 |
BC |
23.1 |
LDPE |
36/12/0.255 |
|
BC |
28.5± 0.40 |
PVC |
52 |
96.8 |
22 |
328 |
100 |
RG-19A/U |
- |
1/6.35 |
BC |
23.1 |
LDPE |
36/12/0.255 |
|
BC |
28.5± 0.40 |
NC- PVC |
52 |
96.8 |
22 |
328 |
100 |
RG-22/U |
- |
7/0.386? 2c |
BC |
7.24 |
LDPE |
24/8/0.18 |
|
BC |
10.3± 0.20 |
PVC |
95 |
52.5 |
118 |
328 |
100 |
RG-22A/U |
- |
7/0.386? 2c |
BC |
7.24 |
LDPE |
24/8/0.16 |
24/8/0.16 |
BC |
10.7± 0.20 |
PVC |
95 |
52.5 |
118 |
328 |
100 |
RG-22B/U |
- |
7/0.386? 2c |
BC |
7.24 |
LDPE |
24/80.16 |
24/8/0.16 |
BC |
10.7± 0.20 |
NC- PVC |
95 |
52.5 |
118 |
328 |
100 |
RG-29/U |
1354 |
1/0.813 |
BC |
2.95 |
LDPE |
16/7/0.127 |
|
BC |
4.7± 0.15 |
PE |
53.5 |
93.5 |
138 |
656 |
200 |
RG-34/U |
- |
7/0.724 |
BC |
11.6 |
LDPE |
24/9/0.16 |
|
BC |
15.9± 0.25 |
PVC |
71 |
70.5 |
46 |
328 |
100 |
RG-34B/U |
- |
7/0.632 |
BC |
11.7 |
LDPE |
24/10/0.18 |
|
BC |
16.0± 0.25 |
NC- PVC |
75 |
67.0 |
48 |
328 |
100 |
RG-54A/U |
- |
7/0.386 |
BC |
4.52 |
LDPE |
16/9/0.16 |
|
BC |
6.1± 0.15 |
PE |
58 |
85.8 |
187 |
656 |
200 |
RG-55/U |
- |
1/0.813 |
BC |
2.90 |
LDPE |
16/7/0.127 |
16/8/0.127 |
BC |
5.0± 0.15 |
PE |
53.5 |
93.6 |
138 |
656 |
200 |
RG-58/U |
1354 |
1/0.813 |
BC |
2.95 |
LDPE |
16/8/0.127 |
|
TC |
4.95± 0.15 |
PVC |
53.5 |
93.5 |
138 |
656 |
200 |
RG-58A/U |
1354 |
19/0.18 |
TC |
2.95 |
LDPE |
16/8/0.127 |
|
TC |
4.95± 0.15 |
PVC |
50 |
93.5 |
176 |
656 |
200 |
RG-58C/U |
1354 |
19/0.18 |
TC |
2.95 |
LDPE |
16/8/0.127 |
|
TC |
4.95± 0.15 |
NC- PVC |
50 |
93.5 |
176 |
656 |
200 |
RG-59/U |
1354 |
1/0.643 |
CCS |
3.71 |
LDPE |
16/7/0.16 |
|
BC |
6.15± 0.15 |
PVC |
73 |
68.9 |
125 |
656 |
200 |
RG-59A/U |
1354 |
1/0.643 |
CCS |
3.71 |
LDPE |
16/7/0.16 |
|
TC |
6.15± 0.15 |
NC- PVC |
73 |
68.9 |
125 |
656 |
200 |
RG-59B/U |
1071 |
1/0.584 |
CCS |
3.71 |
LDPE |
16/7/0.16 |
|
BC |
6.15± 0.15 |
NC- PVC |
93 |
68.9 |
112 |
656 |
200 |
RG-62/U |
1354 |
1/0.643 |
CCS |
3.71 |
LDPE |
16/7/0.16 |
|
BC |
6.15± 0.15 |
PVC |
93 |
44.3 |
102 |
656 |
200 |
RG-62A/U |
1478 |
1/0.643 |
CCS |
3.71 |
LDPE |
16/7/0.16 |
|
BC |
6.15± 0.15 |
NC- PVC |
125 |
32.8 |
66 |
656 |
200 |
RG-63/U |
- |
1/0.643 |
CCS |
7.24 |
LDPE |
24/8/0.18 |
|
BC |
10.3± 0.20 |
PVC |
215 |
32.8 |
66 |
328 |
100 |
RG-63B/U |
- |
1/0.643 |
CCS |
7.24 |
LDPE |
24/8/0.18 |
|
BC |
10.3± 0.20 |
NC- PVC |
125 |
32.8 |
66 |
328 |
100 |
RG-71/U |
1354 |
1/0.643 |
CCS |
3.71 |
LDPE |
16/7/0.16 |
16/8/0.127 |
BC |
6.4± 0.15 |
PE |
93 |
44.3 |
102 |
328 |
100 |
RG-89/U |
- |
1/0.643 |
CCS |
7.24 |
LDPE |
16/12/0.18 |
|
BC |
16.0± 0.25 |
PVC |
125 |
32.8 |
66 |
328 |
100 |
RG-108/U |
- |
7/0.32? 2c |
TC |
1.84 |
LDPE |
16/6/0.127 |
|
BC |
6.2± 0.15 |
NC- PVC |
78 |
74.3 |
- |
656 |
200 |
RG-108A/U |
- |
7/0.32? 2c |
TC |
2.01 |
LDPE |
16/6/0.127 |
|
BC |
5.97± 0.15 |
NC- PVC |
78 |
74.3 |
- |
656 |
200 |
RG-122/U |
1354 |
27/0.127 |
TC |
2.44 |
LDPE |
16/6/0.127 |
|
BC |
4.06± 0.15 |
NC- PVC |
50 |
105 |
195 |
328 |
100 |
RG-130/U |
- |
7/0.724? 2c |
BC |
12.0 |
LDPE |
24/8/0.255 |
|
BC |
15.9± 0.15 |
PVC |
95 |
56 |
99 |
328 |
100 |
RG-133A/U |
- |
1/0.645 |
BC |
7.2 |
LDPE |
24/8/0.18 |
|
BC |
10.3± 0.20 |
NC- PVC |
95 |
53 |
76 |
328 |
100 |
RG-164/U |
- |
1/2.65 |
BC |
17.3 |
LDPE |
24/14/0.255 |
|
BC |
22.1± 0.35 |
NC- PVC |
75 |
67 |
30 |
328 |
100 |
RG-174/U |
1354 |
7/0.16 |
CCS |
1.52 |
LDPE |
16/5/0.10 |
|
TC |
2.54± 0.15 |
NC- PVC |
50 |
110 |
259 |
2000 |
500 |
RG-213/U |
- |
7/0.752 |
BC |
7.24 |
LDPE |
24/8/0.18 |
|
BC |
10.3± 0.20 |
NC- PVC |
50 |
100 |
67 |
328 |
100 |
RG-216/U |
- |
7/0.404 |
TC |
7.24 |
LDPE |
24/9/0.16 |
24/8/0.16 |
BC |
10.8± 0.20 |
NC- PVC |
75 |
67 |
88 |
328 |
100 |
RG-217/U |
- |
1/2.69 |
BC |
9.4 |
LDPE |
24/10/0.18 |
24/8/0.18 |
BC |
13.8± 0.25 |
NC- PVC |
50 |
100 |
50 |
328 |
100 |
Attenuation is measured at 100MHz
BC: bare copper wired
CCS : copper clad steel wire
TC : tinned copper wire
NC-PVC : non-contamnating polyvinyl choride |
PE: polyethylene
PVC:polyvinyl choride
LDPE: low density polyethylene
LDPEF : low density polyethylene foam |
|
| |
|
|
|